Sec. 1910.68  Manlifts.


    (a) Definitions applicable to this section--(1) Handhold (Handgrip). 

A handhold is a device attached to the belt which can be grasped by the 

passenger to provide a means of maintaining balance.



[[Page 188]]



    (2) Open type. One which has a handgrip surface fully exposed and 

capable of being encircled by the passenger's fingers.

    (3) Closed type. A cup-shaped device, open at the top in the 

direction of travel of the step for which it is to be used, and closed 

at the bottom, into which the passenger may place his fingers.

    (4) Limit switch. A device, the purpose of which is to cut off the 

power to the motor and apply the brake to stop the carrier in the event 

that a loaded step passes the terminal landing.

    (5) Manlift. A device consisting of a power-driven endless belt 

moving in one direction only, and provided with steps or platforms and 

handholds attached to it for the transportation of personnel from floor 

to floor.

    (6) Rated speed. Rated speed is the speed for which the device is 

designed and installed.

    (7) Split-rail switch. An electric limit switch operated 

mechanically by the rollers on the manlift steps. It consists of an 

additional hinged or ``split'' rail, mounted on the regular guide rail, 

over which the step rollers pass. It is springloaded in the ``split'' 

position. If the step supports no load, the rollers will ``bump'' over 

the switch; if a loaded step should pass over the section, the split 

rail will be forced straight, tripping the switch and opening the 

electrical circuit.

    (8) Step (platform). A step is a passenger carrying unit.

    (9) Travel. The travel is the distance between the centers of the 

top and bottom pulleys.

    (b) General requirements--(1) Application. This section applies to 

the construction, maintenance, inspection, and operation of manlifts in 

relation to accident hazards. Manlifts covered by this section consist 

of platforms or brackets and accompanying handholds mounted on, or 

attached to an endless belt, operating vertically in one direction only 

and being supported by, and driven through pulleys, at the top and 

bottom. These manlifts are intended for conveyance of persons only. It 

is not intended that this section cover moving stairways, elevators with 

enclosed platforms (``Paternoster'' elevators), gravity lifts, nor 

conveyors used only for conveying material. This section applies to 

manlifts used to carry only personnel trained and authorized by the 

employer in their use.

    (2) Purpose. The purpose of this section is to provide reasonable 

safety for life and limb.

    (3) Design requirements. All new manlift installations and equipment 

installed after the effective date of these regulations shall meet the 

design requirements of the ``American National Safety Standard for 

Manlifts ANSI A90.1-1969'', which is incorporated by reference as 

specified in Sec. 1910.6, and the requirements of this section.

    (4) Reference to other codes and subparts. The following codes, and 

subparts of this part, are applicable to this section: Safety Code for 

Mechanical Power Transmission Apparatus, ANSI B15.1-1953 (R 1958), and 

subpart O; subpart S; Safety Code for Fixed Ladders, ANSI A14.3-1956, 

and Safety Requirements for Floor and Wall Openings, Railings and 

Toeboards, ANSI A12.1-1967, and subpart D. The preceding ANSI standards 

are incorporated by reference as specified in Sec. 1910.6.

    (5) Floor openings--(i) Allowable size. Floor openings for both the 

``up'' and ``down'' runs shall be not less than 28 inches nor more than 

36 inches in width for a 12-inch belt; not less than 34 inches nor more 

than 38 inches for a 14-inch belt; and not less than 36 inches nor more 

than 40 inches for a 16-inch belt and shall extend not less than 24 

inches, nor more than 28 inches from the face of the belt.

    (ii) Uniformity. All floor openings for a given manlift shall be 

uniform in size and shall be approximately circular, and each shall be 

located vertically above the opening below it.

    (6) Landing--(i) Vertical clearance. The clearanace between the 

floor or mounting platform and the lower edge for the conical guard 

above it required by subparagraph (7) of this paragraph shall not be 

less than 7 feet 6 inches. Where this clearance cannot be obtained no 

access to the manlift shall be provided and the manlift runway shall be 

enclosed where it passes through such floor.

    (ii) Clear landing space. The landing space adjacent to the floor 

openings shall be free from obstruction and kept



[[Page 189]]



clear at all times. This landing space shall be at least 2 feet in width 

from the edge of the floor opening used for mounting and dismounting.

    (iii) Lighting and landing. Adequate lighting, not less than 5-foot 

candles, shall be provided at each floor landing at all times when the 

lift is in operation.

    (iv) Landing surface. The landing surfaces at the entrances and 

exits to the manlift shall be constructed and maintained as to provide 

safe footing at all times.

    (v) Emergency landings. Where there is a travel of 50 feet or more 

between floor landings, one or more emergency landings shall be provided 

so that there will be a landing (either floor or emergency) for every 25 

feet or less of manlift travel.

    (a) Emergency landings shall be accessible from both the ``up'' and 

``down'' rungs of the manlift and shall give access to the ladder 

required in subparagraph (12) of this paragraph.

    (b) Emergency landings shall be completely enclosed with a standard 

railing and toeboard.

    (c) Platforms constructed to give access to bucket elevators or 

other equipment for the purpose of inspection, lubrication, and repair 

may also serve as emergency landings under this rule. All such platforms 

will then be considered part of the emergency landing and shall be 

provided with standard railings and toeboards.

    (7) Guards on underside of floor openings--(i) Fixed type. On the 

ascending side of the manlift floor openings shall be provided with a 

bevel guard or cone meeting the following requirements:

    (a) The cone shall make an angle of not less than 45[deg] with the 

horizontal. An angle of 60[deg] or greater shall be used where ceiling 

heights permit.

    (b) The lower edge of this guard shall extend at least 42 inches 

outward from any handhold on the belt. It shall not extend beyond the 

upper surface of the floor above.

    (c) The cone shall be made of not less than No. 18 U.S. gauge sheet 

steel or material of equivalent strength or stiffness. The lower edge 

shall be rolled to a minimum diameter of one-half inch and the interior 

shall be smooth with no rivets, bolts or screws protruding.

    (ii) Floating type. In lieu of the fixed guards specified in 

subdivision (i) of this subparagraph a floating type safety cone may be 

used, such floating cones to be mounted on hinges at least 6 inches 

below the underside of the floor and so constructed as to actuate a 

limit switch should a force of 2 pounds be applied on the edge of the 

cone closest to the hinge. The depth of this floating cone need not 

exceed 12 inches.

    (8) Protection of entrances and exits--(i) Guard rail requirement. 

The entrances and exits at all floor landings affording access to the 

manlift shall be guarded by a maze (staggered railing) or a handrail 

equipped with self-closing gates.

    (ii) Construction. The rails shall be standard guardrails with 

toeboards meeting the provisions of the Safety Requirements for Floor 

and Wall Openings, Railings and Toeboards, ANSI A12.1-1967 and Sec. 

1910.23.

    (iii) Gates. Gates, if used, shall open outward and shall be self-

closing. Corners of gates shall be rounded.

    (iv) Maze. Maze or staggered openings shall offer no direct passage 

between enclosure and outer floor space.

    (v) Except where building layout prevents, entrances at all landings 

shall be in the same relative position.

    (9) Guards for openings--(i) Construction. The floor opening at each 

landing shall be guarded on sides not used for entrance or exit by a 

wall, a railing and toeboard or by panels of wire mesh of suitable 

strength.

    (ii) Height and location. Such rails or guards shall be at least 42 

inches in height on the up-running side and 66 inches on the down-

running side.

    (10) Bottom arrangement--(i) Bottom landing. At the bottom landing 

the clear area shall be not smaller than the area enclosed by the 

guardrails on the floors above, and any wall in front of the down-

running side of the belt shall be not less than 48 inches from the face 

of the belt. This space shall not be encroached upon by stairs or 

ladders.

    (ii) Location of lower pulley. The lower (boot) pulley shall be 

installed so that it is supported by the lowest landing served. The 

sides of the pulley support



[[Page 190]]



shall be guarded to prevent contact with the pulley or the steps.

    (iii) Mounting platform. A mounting platform shall be provided in 

front or to one side of the uprun at the lowest landing, unless the 

floor level is such that the following requirement can be met: The floor 

or platform shall be at or above the point at which the upper surface of 

the ascending step completes its turn and assumes a horizontal position.

    (iv) Guardrails. To guard against persons walking under a descending 

step, the area on the downside of the manlift shall be guarded in 

accordance with subparagraph (8) of this paragraph. To guard against a 

person getting between the mounting platform and an ascending step, the 

area between the belt and the platform shall be protected by a 

guardrail.

    (11) Top arrangements--(i) Clearance from floor. A top clearance 

shall be provided of at least 11 feet above the top terminal landing. 

This clearance shall be maintained from a plane through each face of the 

belt to a vertical cylindrical plane having a diameter 2 feet greater 

than the diameter of the floor opening, extending upward from the top 

floor to the ceiling on the up-running side of the belt. No encroachment 

of structural or machine supporting members within this space will be 

permitted.

    (ii) Pulley clearance. (a) There shall be a clearance of at least 5 

feet between the center of the head pulley shaft and any ceiling 

obstruction.

    (b) The center of the head pulley shaft shall be not less than 6 

feet above the top terminal landing.

    (iii) Emergency grab rail. An emergency grab bar or rail and 

platform shall be provided at the head pulley when the distance to the 

head pulley is over 6 feet above the top landing, otherwise only a grab 

bar or rail is to be provided to permit the rider to swing free should 

the emergency stops become inoperative.

    (12) Emergency exit ladder. A fixed metal ladder accessible from 

both the ``up'' and ``down'' run of the manlift shall be provided for 

the entire travel of the manlift. Such ladder shall be in accordance 

with the existing ANSI A14.3-1956 Safety Code for Fixed Ladders and 

Sec. 1910.27.

    (13) Superstructure bracing. Manlift rails shall be secured in such 

a manner as to avoid spreading, vibration, and misalinement.

    (14) Illumination--(i) General. Both runs of the manlift shall be 

illuminated at all times when the lift is in operation. An intensity of 

not less than 1-foot candle shall be maintained at all points. (However, 

see subparagraph (6)(iii) of this paragraph for illumination 

requirements at landings.)

    (ii) Control of illumination. Lighting of manlift runways shall be 

by means of circuits permanently tied in to the building circuits (no 

switches), or shall be controlled by switches at each landing. Where 

separate switches are provided at each landing, any switch shall turn on 

all lights necessary to illuminate the entire runway.

    (15) Weather protection. The entire manlift and its driving 

mechanism shall be protected from the weather at all times.

    (c) Mechanical requirements--(1) Machines, general--(i) Brakes. 

Brakes provided for stopping and holding a manlift shall be inherently 

self-engaging, by requiring power or force from an external source to 

cause disengagement. The brake shall be electrically released, and shall 

be applied to the motor shaft for direct-connected units or to the input 

shaft for belt-driven units. The brake shall be capable of stopping and 

holding the manlift when the descending side is loaded with 250 lb on 

each step.

    (ii) Belt. (a) The belts shall be of hard-woven canvas, rubber-

coated canvas, leather, or other material meeting the strength 

requirements of paragraph (b)(3) of this section and having a 

coefficient of friction such that when used in conjunction with an 

adequate tension device it will meet the brake test specified in 

subdivision (i) of this subparagraph.

    (b) The width of the belt shall be not less than 12 inches for a 

travel not exceeding 100 feet, not less than 14 inches for a travel 

greater than 100 feet but not exceeding 150 feet and 16 inches for a 

travel exceeding 150 feet.



[[Page 191]]



    (c) A belt that has become torn while in use on a manlift shall not 

be spliced and put back in service.

    (2) Speed--(i) Maximum speed. No manlift designed for a speed in 

excess of 80 feet per minute shall be installed.

    (ii) [Reserved]

    (3) Platforms or steps--(i) Minimum depth. Steps or platforms shall 

be not less than 12 inches nor more than 14 inches deep, measured from 

the belt to the edge of the step or platform.

    (ii) Width. The width of the step or platform shall be not less than 

the width of the belt to which it is attached.

    (iii) Distance between steps. The distance between steps shall be 

equally spaced and not less than 16 feet measured from the upper surface 

of one step to the upper surface of the next step above it.

    (iv) Angle of step. The surface of the step shall make approximately 

a right angle with the ``up'' and ``down'' run of the belt, and shall 

travel in the approximate horizontal position with the ``up'' and 

``down'' run of the belt.

    (v) Surfaces. The upper or working surfaces of the step shall be of 

a material having inherent nonslip characteristics (coefficient of 

friction not less than 0.5) or shall be covered completely by a nonslip 

tread securely fastened to it.

    (vi) Strength of step supports. When subjected to a load of 400 

pounds applied at the approximate center of the step, step frames, or 

supports and their guides shall be of adequate strength to:

    (a) Prevent the disengagement of any step roller.

    (b) Prevent any appreciable misalinement.

    (c) Prevent any visible deformation of the steps or its support.

    (vii) Prohibition of steps without handholds. No steps shall be 

provided unless there is a corresponding handhold above or below it 

meeting the requirements of paragraph (c)(4) of this section. If a step 

is removed for repairs or permanently, the handholds immediately above 

and below it shall be removed before the lift is again placed in 

service.

    (4) Handholds--(i) Location. Handholds attached to the belt shall be 

provided and installed so that they are not less than 4 feet nor more 

than 4 feet 8 inches above the step tread. These shall be so located as 

to be available on the both ``up'' and ``down'' run of the belt.

    (ii) Size. The grab surface of the handhold shall be not less than 

4\1/2\ inches in width, not less than 3 inches in depth, and shall 

provide 2 inches of clearance from the belt. Fastenings for handholds 

shall be located not less than 1 inch from the edge of the belt.

    (iii) Strength. The handhold shall be capable of withstanding, 

without damage, a load of 300 pounds applied parallel to the run of the 

belt.

    (iv) Prohibition of handhold without steps. No handhold shall be 

provided without a corresponding step. If a handhold is removed 

permanently or temporarily, the corresponding step and handhold for the 

opposite direction of travel shall also be removed before the lift is 

again placed in service.

    (v) Type. All handholds shall be of the closed type.

    (5) Up limit stops--(i) Requirements. Two separate automatic stop 

devices shall be provided to cut off the power and apply the brake when 

a loaded step passes the upper terminal landing. One of these shall 

consist of a split-rail switch mechanically operated by the step roller 

and located not more than 6 inches above the top terminal landing. The 

second automatic stop device may consist of any of the following:

    (a) Any split-rail switch placed 6 inches above and on the side 

opposite the first limit switch.

    (b) An electronic device.

    (c) A switch actuated by a lever, rod, or plate, the latter to be 

placed on the ``up'' side of the head pulley so as to just clear a 

passing step.

    (ii) Manual reset location. After the manlift has been stopped by a 

stop device it shall be necessary to reset the automatic stop manually. 

The device shall be so located that a person resetting it shall have a 

clear view of both the ``up'' and ``down'' runs of the manlift. It shall 

not be possible to reset the device from any step or platform.

    (iii) Cut-off point. The initial limit stop device shall function so 

that the



[[Page 192]]



manlift will be stopped before the loaded step has reached a point 24 

inches above the top terminal landing.

    (iv) Electrical requirements. (a) Where such switches open the main 

motor circuit directly they shall be of the multipole type.

    (b) Where electronic devices are used they shall be so designed and 

installed that failure will result in shutting off the power to the 

driving motor.

    (c) Where flammable vapors or combustible dusts may be present, 

electrical installations shall be in accordance with the requirements of 

subpart S of this part for such locations.

    (d) Unless of the oil-immersed type controller contacts carrying the 

main motor current shall be copper to carbon or equal, except where the 

circuit is broken at two or more points simultaneously.

    (6) Emergency stop--(i) General. An emergency stop means shall be 

provided.

    (ii) Location. This stop means shall be within easy reach of the 

ascending and descending runs of the belt.

    (iii) Operation. This stop means shall be so connected with the 

control lever or operating mechanism that it will cut off the power and 

apply the brake when pulled in the direction of travel.

    (iv) Rope. If rope is used, it shall be not less than three-eights 

inch in diameter. Wire rope, unless marlin-covered, shall not be used.

    (7) Instruction and warning signs--(i) Instruction signs at landings 

or belts. Signs of conspicuous and easily read style giving instructions 

for the use of the manlift shall be posted at each landing or stenciled 

on the belt.

    (a) [Reserved]

    (b) The instructions shall read approximately as follows:



Face the Belt.

Use the Handholds.

To Stop--Pull Rope.



    (ii) Top floor warning sign and light. (a) At the top floor an 

illuminated sign shall be displayed bearing the following wording:



``TOP FLOOR--GET OFF''





Signs shall be in block letters not less than 2 inches in height. This 

sign shall be located within easy view of an ascending passenger and not 

more than 2 feet above the top terminal landing.

    (b) In addition to the sign required by paragraph (c)(7)(ii)(a) of 

this section, a red warning light of not less than 40- watt rating shall 

be provided immediately below the upper landing terminal and so located 

as to shine in the passenger's face.

    (iii) Visitor warning. A conspicuous sign having the following 

legend--AUTHORIZED PERSONNEL ONLY--shall be displayed at each landing.

    (d) Operating rules--(1) Proper use of manlifts. No freight, 

packaged goods, pipe, lumber, or construction materials of any kind 

shall be handled on any manlift.

    (2) [Reserved]

    (e) Periodic inspection--(1) Frequency. All manlifts shall be 

inspected by a competent designated person at intervals of not more than 

30 days. Limit switches shall be checked weekly. Manlifts found to be 

unsafe shall not be operated until properly repaired.

    (2) Items covered. This periodic inspection shall cover but is not 

limited to the following items:



Steps.

Step Fastenings.

Rails.

Rail Supports and Fastenings.

Rollers and Slides.

Belt and Belt Tension.

Handholds and Fastenings.

Floor Landings.

Guardrails.

Lubrication.

Limit Switches.

Warning Signs and Lights.

Illumination.

Drive Pulley.

Bottom (boot) Pulley and Clearance.

Pulley Supports.

Motor.

Driving Mechanism.

Brake.

Electrical Switches.

Vibration and Misalignment.

``Skip'' on up or down run when mounting step (indicating worn gears).



    (3) Inspection record. A certification record shall be kept of each 

inspection which includes the date of the inspection, the signature of 

the person who performed the inspection and the serial number, or other 

identifier, of the manlift which was inspected. This record of 

inspection shall be made available to the Assistant Secretary of



[[Page 193]]



Labor or a duly authorized representative.